Selfextinguishing installation corrugated conduit RIS-PA6-HB (-P)

#
#
#
EU designation (EN 61386-1): 33442
Material: self-extinguishing polyamide 6 (PA6)
Mechanical strength: medium (750N) 3
Impact resistance: medium (2,0 kg/100mm) 3
Temperature range (transportation, application, installation):
minimum temperature: -25 °C 4
maximum temperature: +120 °C (Intermittent +180 °C) 4
Flexibility: pliable 2
Colours: transparent white, black other colours on request
Flammability: HB UL94, The flammability of all types of nylon conduit can be modified on request: V-0, V-1, V-2, HB according to UL-94.
Application:Conduit designed for cable protection in building, industrial applications and automotive wiring systems. Recomended for installations and places with an increased risk of fire hazard (wooden constructions, lofts, garrets, etc.) and tightened security against toxic chemical compounds (halogen free). Highly flexible, it can be used in places not easily accessible. It ensures high strength and resistance to mechanical factors. Smooth inner profile enables easy cable installation and replacement in long sections. Conduit is available in versions:
- standard (RIL-PA6-HB, RIS-PA6-HB)
- with a guide pin: a wire to facilitate drawing conductors into (RIL-PA6-HB-P, RIS-PA6-HB-P).
For automotive market, conduit is available longitudinally cut on request.
Characteristics of materialFree from halogen, phosphorus and cadmium, self-extinguishing/flame retardant, high-bending and crack resistance, well balanced elongation and elasticity behaviour as well as high abrasion-resistance, high tensile strength, rigidity, high impact strength, very large thermal resistance, resistance to the most of chemical compounds.

Materials:
PA6.6, PA4.6, PA11, PA12 available on request
 
 
 
 
 
 

The specification can be subject of change without notice.

European standard diameters

Nominal diameter DN Inside diameter (mm) Outside diameter (mm)) Coil length (m)
16 10,5 16 25,50,100
20 15 20 25,50,100
25 19 25 25,50
32 26 32 25,50
40 33 40 25,50
50 43 50 25
63 54 63 25

All available diameters

Nominal diameter DN Inside diameter (mm) Outside diameter (mm)) Coil length (m)
7 4,5 7 100,200
10 7 10 50,100
14 9 14 25,50,100
15 11 15 25,50,100
16 10,5 16 25,50,100
18 13 18 25,50,100
20 15 20 25,50,100
21 16 21 25,50,100
22 18 22 25,50,100
25 19 25 25,50
28 23 28 25,50
32 26 32 25,50
36 29 36 25,50
39 32 39 25
40 33 40 25
43 36 43 25
47 40 47 25
50 43 50 25
52 44 52 25
54 44 52 25
63 54 63 25
high medium none
Acids weak
strong
oxidising
hydrofluoric
Bases dry halogens
weak
strong
Solvents alkohols
esters
ketones
ethers
chlorinated hydrocarbons
Oils and diesel materials benzene
petrol
diesel mixtures
mineral oils
fatty oils
recommended admissible shoud not be used
Wall installations
Sunk installations
Outer wall installations
Plaster walls
Combustible surfaces (wood, etc.)
Underground installations
Poured concrete
Vibrated concrete
Steamed and vibrated concrete
Electrotechnical equipment
Industrial apparatus, control and automatics
Food and chemical industry facilities
Automotive industry
Shipyard industry
Aircraft industry
http://www.ingremio.com.pl/sites/default/files/RIL-PA6-HB, RIS-PA6-HB_0.pdf