Nowoczesna myśl techniczna

Selfextinguishing installation corrugated conduit RKLG - P

#
#
#
EU designation (EN 61386-1): 22312
Material: polyvinyl chloride (PVC-mod.), lead-free on request
Mechanical strength: light (320N) 2
Impact resistance: light (1,0 kg/100mm) 2
Temperature range (transportation, application, installation):
minimum temperature: -15 °C 3
maximum temperature: +60 °C 1
Flexibility: pliable 2
Colours: grey, other colours on request
Application:Conduit designed for cable protection in building and industrial applications. Recommended for sunk wiring systems, external installations and places with an increased risk of fire hazard (wooden constructions, lofts, garrets, etc.). The RKSG type commonly used in vibrated concrete. It ensures high strength and resistance to mechanical factors. In spite of light strength it features high flexibility. Smooth inner profile enables easy cable installation in long sections. Conduit is available in versions:
- standard (RKLG)
- with draw wire to enable cables to be pulled through (RKLG-P).
Characteristics of materialSelf-extinguishing/flame retardant material, medium tensile strength, medium rigidity, high impact strength, high thermal resistance, resistant to the most of chemical compounds, good dielectric properties within a wide temperature range even in a wet environment, high water absorption resistance, inconsiderable deformability.
 
 
 
 
 
 

The specification can be subject of change without notice.

European standard diameters

Nominal diameter DN Inside diameter (mm) Outside diameter (mm)) Coil length (m)
16 10,5 16 25,50,100
20 15 20 25,50,100
25 19 25 25,50
32 26 32 25,50
40 33 40 25,50
50 43 50 25
63 54 63 25

All available diameters

Nominal diameter DN Inside diameter (mm) Outside diameter (mm)) Coil length (m)
15 11 15 25,50,100
16 10,5 16 25,50,100
18 13 18 25,50,100
20 15 20 25,50,100
21 16 21 25,50,100
22 18 22 25,50,100
25 19 25 25,50
28 23 28 25,50
32 26 32 25,50
36 29 36 25,50
39 32 39 25
40 33 40 25
43 36 43 25
47 40 47 25
50 43 50 25
52 44 52 25
54 44 52 25
63 54 63 25
high medium none
Acids weak
strong
oxidising
hydrofluoric
Bases dry halogens
weak
strong
Solvents alkohols
esters
ketones
ethers
chlorinated hydrocarbons
Oils and diesel materials benzene
petrol
diesel mixtures
mineral oils
fatty oils
recommended admissible shoud not be used
Wall installations
Sunk installations
Outer wall installations
Plaster walls
Combustible surfaces (wood, etc.)
Underground installations
Poured concrete
Vibrated concrete
Steamed and vibrated concrete
Electrotechnical equipment
Industrial apparatus, control and automatics
Food and chemical industry facilities
Automotive industry
Shipyard industry
Aircraft industry
http://www.ingremio.com.pl/sites/default/files/RKLG(P) RKSG(P) -EN.pdf